DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter

Product Details
Customization: Available
After-sales Service: Yes
Warranty: Yes
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter
  • DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter
  • DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter
  • DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter
Find Similar Products
  • Overview
  • Product Description
  • Company Information
Overview

Basic Info.

Model NO.
DC430
Display
Digital
Installation
Direct Connected
Usage
Multi-Functional Energy Meter
Electric Equipment
Single-phase
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
CE
Customized
Customized
Condition
100%Brand
Nodel Number
DC430
Payment Way
Union Moneygram Escrow Tt Paypal
Single Gross Weight
0.350kg
Product Name
DC430
Lace of Origin
Guangdong,China
Single Package Size
22X20X15.Cm
Application
Electronic Products
Transport Package
Standard Packing
Specification
/
Trademark
OEM
Origin
China
HS Code
0000000
Production Capacity
50000PCS/ Month

Packaging & Delivery

Package Size
22.00cm * 20.00cm * 10.00cm
Package Gross Weight
0.350kg

Product Description

Product Description

Product features:

Supports cumulative data reset and forced zero reset with no load
Supports voltage display fine tuning and current display fine tuning
Columnar temperature waterproof probe, temperature measurement range -40~120
High definition IPS LCD color screen with a resolution of 135 * 240
Can simultaneously measure voltage, current, power, percentage, electricity, temperature, cumulative capacity, energy, operating time

10A technical parameters:
Instrument working voltage: XH-3P red black wire DC4~30V (do not overvoltage power supply)
Introduction to Wire Definition:
XH-2.54-3P red black yellow wire (total length of thin wire: 155mm)
Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V
Thin black wire: The negative pole of the working power supply is grounded together with the thick black wire, and there is no need to connect it when sharing the power supply
Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply
VH-3.96-2P thick red black wire (total length of thick wire: 165mm) current test wire, parallel shunt resistor of thick wire, cannot be directly connected to the two poles of the power supply, and may cause short circuit
Thick red wire: current test positive pole, connected in series at the back end of the negative pole of the load, and connected first and then disconnected when connecting the wire
Thick black wire: current test negative pole, connect to the negative pole of the power supply, and connect the broken wire first and then disconnect it
Connection diverter: On board low-temperature drift alloy resistance shunt, can be directly connected according to the wiring diagram
Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump
Current measurement range: 0.00A~10.00A Error ± 0.1A 0.03A Jump
Power measurement range: 00.00~1000W
Capacity measurement range: 0~9999999mAh
Energy metering range: 0~9999999mWh
Temperature sensor: cylindrical waterproof probe NTC 10K 3950 1% sensor with a total length of approximately 1 meter
Temperature measurement range: -40~120 (external temperature measured by NTC sensor)
Time measurement range: 0~999:59:59 (hour: minute: second)
Working energy consumption: 20mA (measured at DC12V)
Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment
Percentage battery display: Based on voltage reference, the percentage battery (full and low battery voltages need to be manually set)
Product size: 47.59 × twenty-eight point six seven × 25.33mm
Installation hole: 45 × 26mm

50A technical parameters:
Instrument working voltage: XH-3P red black wire DC4~30V (do not overvoltage power supply)
Introduction to Wire Definition:
XH-2.54-3P red black yellow wire (total length of thin wire: 155mm)
Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V
Thin black wire: The negative pole of the working power supply is grounded together with the thick black wire, and there is no need to connect it when sharing the power supply
Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply
VH-3.96-2P thick red black wire (total length of thick wire: 165mm) current test wire, thick wire cannot be directly connected to the two poles of the power supply, which will cause a short circuit
Thick red line: current test positive pole, parallel shunt connected to the rear end of the negative pole of the load
Thick black wire: current test negative pole, parallel shunt connected to power negative pole
Connecting the splitter: A parallel 50A 75mV splitter is required to use (the splitter needs to be provided by oneself)
Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump
Current measurement range: 0.00A~50.00A Error ± 0.5A 0.03A Jump
Power measurement range: 00.00~5000W
Capacity measurement range: 0~9999999mAh
Energy metering range: 0~9999999mWh
Temperature sensor: cylindrical waterproof probe NTC 10K 3950 1% sensor with a total length of approximately 1 meter
Temperature measurement range: -40~120 (external temperature measured by NTC sensor)
Time measurement range: 0~999:59:59 (hour: minute: second)
Working energy consumption: 20mA (measured at DC12V)
Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment
Percentage battery display: Based on voltage reference, the percentage battery (full and low battery voltages need to be manually set)
Product size: 47.59 × twenty-eight point six seven × 25.33mm
Installation hole: 45 × 26mm

100A technical parameters:
Instrument working voltage: XH-3P red black wire DC4~30V (do not overvoltage power supply)
Introduction to Wire Definition:
XH-2.54-3P red black yellow wire (total length of thin wire: 155mm)
Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V
Thin black wire: The negative pole of the working power supply is grounded together with the thick black wire, and there is no need to connect it when sharing the power supply
Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply
VH-3.96-2P thick red black wire (total length of thick wire: 165mm) current test wire
The parallel shunt resistor with thick wires cannot be directly connected to the two poles of the power supply, which may cause a short circuit
Thick red line: current test positive pole, parallel shunt connected to the negative end of the load in series.
Thick black wire: current test negative pole, parallel shunt connected to power negative pole.
Connecting the splitter: A parallel 100A 75mV splitter is required to use (the splitter needs to be provided by oneself)
Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump
Current measurement range: 0.00A~50.00A Error ± 1A 0.03A Jump
Power measurement range: 00.00~9999W
Capacity measurement range: 0~9999999mAh
Energy metering range: 0~9999999mWh
Temperature sensor: cylindrical waterproof probe NTC 10K 3950 1% sensor with a total length of approximately 1 meter
Temperature measurement range: -40~120 (external temperature measured by NTC sensor)
Time measurement range: 0~999:59:59 (hour: minute: second)
Working energy consumption: 20mA (measured at DC12V)
Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment
Percentage battery display: Based on voltage reference, the percentage battery (full and low battery voltages need to be manually set)
Product size: 47.59 × twenty-eight point six seven × 25.33mm
Installation hole: 45 × 26mm

Shipping list:
Measuring instrument X1
Column waterproof probe sensing line X1
XH-2.54-3P red black yellow wire X1
VH-3.96-2P thick red black wire X1
Condition new
Wrranty 180 days
DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter
Company Information

With " Quality Focus, Client First" as our core philosophy, Skyriver is found by a team ful of industry experience and knowledge.By Leveraging our deep understanding of the market,we are able to integrate various elements into the product Design,prudcing. The goal of Skyriver is to build a brand combining the features of durability,fashion,elegance and personality, with is also the key factor differentiating us from other competitors.

DC430 10A/50A/100A Multifunction Voltmeter Ammeter Digital Power Energy Meter Wattmeter DC Voltage Current Tester Electric Meter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier