Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | Yes |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main features
1. 9999-count LCD display with analogue bar
2. 250V~1000V DC insulation resistance test
3. 200mA earth-resistance continuity test
4. Loop impedance/Prospective Fault Current (PFC)/Prospective Short Current (PSC) test
5. Lock test
6. RCD trip time test and the data storage with one key
7. Full/Half wave and count downing (30s) test mode selectable
8. 0°/180° phase angle option to detect the fastest trigger time
9. Trip current test of RCD trip time X2
10. RCD trip trigger current test
11. Phase sequence and missing test
12. AC/DC voltage auto check and test
13. Connection check with status real-time display
14. White backlight; auto power off
Functions |
Range |
Accuracy |
|
Open circuit output voltage |
250V |
+-10% |
|
500V |
|||
1000V |
|||
Short circuit current |
2mA |
||
Insulation Resistance Measurement |
250V |
0.01M ohm |
0.05M ohm to 1000M ohm: 5%+5 |
0.1M ohm |
|||
1M ohm |
|||
500V |
0.01M ohm |
||
0.1M ohm |
|||
1M ohm |
|||
1000V |
0.01M ohm |
||
0.1M ohm |
|||
1M ohm |
|||
Grounding (Earthing) continuity measurement |
Range |
0.00 ohm-199 ohm;+-2%+5 |
|
0.00-2 ohm, testing current is more than 200mA |
|||
Line impedance |
Applied voltage |
195V-440V,Frequency: 45Hz-65Hz; |
|
Range |
0.01 ohm-2000 ohm: 5%+5; |
||
Loop impedance |
Applied voltage |
195V-253V,Frequency: 45Hz-65Hz; |
|
Range |
0.01 ohm-2000 ohm: 5%+5; |
||
Loop impedance without tripping |
Applied voltage |
195V-253V,Frequency: 45Hz-65Hz; |
|
Range |
1.00 ohm-2000 ohm: 5%+5; |
||
Testing current |
15mA |
||
RCD measurement |
Applied voltage |
195V-253V,Frequency: 45Hz-65Hz; |
|
Testing current |
10mA,30mA,100mA,300mA,500mA |
||
Accuracy of testing current |
+-10% |
||
Tripping time |
0ms--2000ms, 1/2 delta n |
||
0ms--300ms, I delta n General |
|||
0ms--500ms, I delta n Selective |
|||
0ms--300ms, 2I delta n Selective |
|||
0ms--40ms, 5I delta n |
|||
Accuracy of tripping timee |
+-5%+5 |
||
RAMP Slope RCD measurement |
Test current range |
10mA,30mA,100mA,300mA,500mA |
|
Accuracy of test current |
+-10% |
||
Phase consequence measurement |
Display: |
As per the sequency: L1→ L2→ L3 foreward; L1→ L3→ L2 reserved. |
|
Applied voltage |
100V-440V,frequency: 45Hz-65Hz. |
||
Voltage measurement |
Range and frequency |
Resolution: 1V |
0V--440V/45Hz-60Hz |
Accuracy |
+-5%+2 |
||
Special functions |
|||
AUTO half-wave test |
√ |
||
RCD Coundown test |
30 seconds |
||
RCD half-wave test |
√ |
||
RCD 0°& 180° measurement |
√ |
||
Data storage |
√ |
||
Back light |
√ |
||
Power off automatically |
√ |
||
Low voltage display |
√ |
||
General |
|||
Power supply |
1.5V battery x 8(not included) |
||
LCD size |
125mm x37mm |
||
Color |
red and grey |
||
Weight |
4kg |
||
Meter size |
210mm x 175mm x 90 mm |
||
Accessories |
Test leads(red,green, black), electrical lead,far-end test control lead, case. |
With " Quality Focus, Client First" as our core philosophy, Skyriver is found by a team ful of industry experience and knowledge.By Leveraging our deep understanding of the market,we are able to integrate various elements into the product Design,prudcing. The goal of Skyeriver is to build a brand combining the features of durability,fashion,elegance and personality, with is also the key factor differentiating us from other competitors.