Description:
1. Use high-quality materials, durable
2. Low voltage alarm, high voltage alarm, overcurrent alarm, low capacity alarm
3. Full screen can display all data, more intuitive
4. Hall inductive nondestructive measurement, with ultra simple wiring
5. Easy to use
Parameters:
Current measurement range: 50A/100A/200A/400A (optional)
Power supply voltage range: DC5-120V
Voltage measurement voltage: DC0-300V
Voltage resolution: 0.1V
Capacity measurement range: 0~999AH (Note: 0~2000AH can be reached when only percentage is displayed)
Power measurement range: 0~999KW
Electric energy measurement range: 0~999KWH
Table Measurement error:+- 1%
Refresh speed: 0.5S to refresh the information displayed once
Temperature measurement range: - 50 ° C~125 ° C
Installation slotting size: slotting size: 76.0mm * 40.5mm (20mm in the diameter of sensor threading hole)
Working current: Backlight on: 25MA. Backlight off: 9MA (total power 0.3W, different voltages and currents)
Function introduction:
1. Measure the percentage of remaining battery power (%) and the number of remaining battery power (AH).
2. Measure the DC positive and negative bidirectional current. Measure the DC voltage.
3. Measure the DC positive and negative power.
4. Measure the cumulative electric energy in positive and negative DC directions.
5. Over voltage alarm function, alarm voltage size parameters can be set by yourself. (With alarm sound and alarm output control CN2)
6. Low voltage alarm function, alarm voltage size parameters can be set by yourself. (With alarm sound and alarm output control CN2)
7. Over current alarm function, alarm current size parameters can be set by yourself. (With alarm sound and alarm output control CN2)
8. Low battery remaining power alarm function, and the power icon will flicker constantly, prompting the user to charge. (With alarm sound and alarm output control CN2)
9. Battery over temperature alarm function, and the alarm temperature can be set automatically. (There is an alarm sound and alarm output control CN1, which can be used to control the battery cooling fan. Note: All control output signals are weak signals of 10MA, and the drive equipment needs to be amplified by the customer's external amplifier circuit for control.)
10. Power failure data saving function.
11. Hall sensor is used for isolated measurement, which is safe and reliable, and the wiring installation is very simple and convenient.
Note: Do not interchange sensors!!!
Package included:
Coulometer * 1
Diverter * 1
Connecting wire * 1
Power cord * 1