Product Description
                              
                              1. Current limiting output current range: (0-40A) (0-20A) (0-15A) (0-10A) (0-8A) (0-6A) (0-4A) (0-2.2A) continuous Adjustable
                              2, ripple voltage; no more than 100mV
                              
                              3, the equivalent internal resistance of the regulator: not more than 0.O5Ω
                              
                              
                              4, voltage adjustment rate:
                              
                              
                              5, with short circuit current limit protection, automatic recovery function 
                              
                              
                               
                              
                              
                              Low price and high reliability 
                              
                              
                              105Celsius degree output capacitor 
                              
                              
                              Universal AC input 110/220VAC slected by switch 
                              
                              
                              High efficiency and low operation temperature 
                              
                              
                              Soft-start current can reduce the AC input impact effectively 
                              
                              
                              With short-circuit and overload protection 
                              
                              
                              Compact size,light weight 
                              
                              
                              100% full-load burn-in test 
                              
                              
                              Install with EMI filter,minimum wave  
                              
                              
                              Operational use
                              
                              
                              
                              (How to limit current) to adjust current?
                              
                              
                              1. Operate in the case of power failure, pull the small pull switch in the lower left corner to the current regulating gear
                              
                              
                              2. Pull out (dedicated current regulating insert) to the 2nd and 3rd ports of the wiring port, loosen the port screw with a screwdriver, and tighten with a screwdriver (at this time, connect to the listed power), and then connect The voltage of the meter shows 0.00V, and the current shows the current current parameter. At this time, the power supply will emit a small current.
                              
                              
                              3. On the right side (adjust current knob), you can adjust the desired current limit parameter, and display the current parameter synchronously with the digital display. 0-21A/0-16A/0-11A/0-6.5A can be adjusted in the whole process.
                              
                              
                              4. Remove the (special adjustment current plug) and insert it back into the original insert card holder. After removing the digital display, the voltage is about 0.90V, and the current is 0.00A.
                              
                              
                              5. Pull the pull switch in the lower left corner to the right to open the "open (use)" position.
                              
                              
                              6. The current power supply is in the parameter value of the current limit. The power supply is adjusted to a few V (the digital display shows the output voltage in real time), the current does not change, and the current reaches the current limit of 95% of the current limiting parameter. Overload protection
                              
                              
                              7. The current parameter displayed by the digital display at this time is the current value of the device load, and the load current is monitored in real time. 
                              
                              
                              When the load device is connected, the current value can be adjusted directly in real time. The maximum current value is the maximum current value of the load device. If the current adjustment knob clockwise exceeds the maximum current value of the device, the digital current value will not last. Real-time synchronized digital display, showing only the maximum current value of the device. 
                              
                              
                              If there is no need for current limiting, use the general equipment, without the above operation, pull the pull switch in the lower left corner to the "open (use)" position, and turn the (current adjustment knob) clockwise to the top. The maximum current limit at this time is 21A/16A/11A/6.5A/4A, at this time the power supply parameter is the output 0-24V21A/0-16A/0-48V11A/0-36V15A/0-80V6.5A/0-120V4A, which is equal to a 0-24V20A /0-36V15A/0-48V10A/0-80V6A/0-120V4A switching power supply
                              
                              
                               
                              
                              
                              
                              Uses: Mainly used for various battery charging, DC equipment, DC motor stepless speed regulation, LED stepless dimming, chemical electroplating speed regulation, scientific research test, student experiment, etc., and a wide range of uses.
                              
                              
                              Special attention: If using inductive load such as motor or fan, please pay attention to the maximum starting current parameter of the motor. This parameter must not be higher than the maximum operating current of the power supply. Otherwise, the power supply may be damaged. You should select a higher current power supply or soften the motor. The protection circuit is activated to absorb the inrush current.
                              
                              
                              Power formula) voltage X current = power 
                              
                              
                              
                              Terminal description and wiring method 
                              
                              
                              L, N AC input terminal FG ground mark V+ DC output positive terminal
                              
                              
                              V-DC output negative terminal ADJ adjustable potentiometer Fine-tuning output DC voltage
                              
                              
                               full voltage input
                              
                              
                              Miniaturization
                              
                              
                              Protection function Short circuit / overload / over voltage
                              
                              
                              100% full load aging test
                              
                              
                              Input Voltage & Frequency Range----------110V/220VAC/47~63Hz
                              
                              
                              Start surge current ---------------20A@120VAC (cold start)
                              
                              
                              Output adjustment range --------------- ±100% (rated output voltage)
                              
                              
                              Overload protection -------------------105%~200% (rated load), self-recovery
                              
                              
                              Overvoltage protection -------------------115%~135% (rated output voltage)
                              
                              
                              Short circuit protection ------------------- self-recovery
                              
                              
                              Output start time ---------------≤2S@120VAC ≤1.0S@230VAC
                              
                              
                              Output hold time ---------------≥10mS@120VAC, ≥20mS@230VAC
                              
                              
                              Insulation strength ------------------- Input - Output: AC1500V, 1min
                              
                              
                                                          Input - housing: AC1500V, 1min
                              
                              
                                                          Output - Case: DC500V, 1min
                              
                              
                              Working environment ------------------ -10 ° C ~ 50 ° C; 20% ~ 90% RH (no condensation)
                              
                               
                               
                               
                              
                              
                               
                              
                              
                              
                              Precautions:
                              
                              
                                 When the charger is used, please unplug the battery and turn off the input power. If it is not used for a long time, please store it in a ventilated and dry environment.
                              
                              
                                 To ensure safety, please perform within the line of sight when charging. If you need to leave, remove the battery to avoid unpredictable danger.
                              
                              
                                 Do not mix batteries of different types, different capacities and different manufacturers.
                              
                              
                                  Keep away from flammable materials when charging, pay special attention to battery temperature. If the temperature is very high, such as hot, please disconnect the power immediately to stop charging.
                              
                              
                                  Do not drop wires or other conductive objects into the charger. The consequences are self-sufficient.
                              
                              
                                z Do not charge if the battery leaks, rises drum, peels off, changes color, or deforms.
                              
                              
                                  Do not try to charge a non-rechargeable battery.
                              
                              
                                  Do not exceed the charging range specified by the battery manufacturer. 
                              
                               
                               
                                  Do not modify or disassemble the charger. Turning on the machine and indicating that you have waived all warranty and technical 
                               
                              
                              
                              
                              
                              | Condition | 
                              brand new | 
                              
                              
                              | Warranty | 
                              180 days |